Calculation Data for the Installation Cost of ACT Tape System |
@ |
Wrapping Length of Pipe by ACT Tape System per MAN-DAY |
@ |
@ |
|
@ |
@ |
@ |
@ |
@ |
@ |
@ |
@ |
Providing that pipes are straight and working condition is good ( normal
temp. and good wheather), |
@ |
our estimated man/day is as follows, carring out by skilled worker. |
@ |
@ |
@ |
|
@ |
@ |
@ |
@ |
@ |
@ |
@ |
@ |
1. The procedure of ACT tape 100 system is following 6 steps. |
@ |
@ |
@ |
@ |
@Surface preparation by disc-sander or scrapper |
@ |
@ |
@ |
@ |
@ |
A Under coating of primer- 1st |
@ |
@ |
@ |
@ |
@ |
@ |
BUnder coating of primer-2nd |
CWrapping tape by 55% over
lap |
@ |
@ |
@ |
DMiddle coating of Primer |
ETop coating of top coat |
@ |
@ |
@ |
|
@ |
@ |
@ |
@ |
@ |
@ |
@ |
@ |
2. Man/day |
@ |
@ |
@ |
@ |
@ |
@ |
@ |
1) For strait pipe of dia. 4" or over, except elbow portion |
@ |
@ |
@ |
@ |
In case of 4" or over pipes, 18
square meter ( m2) tape of one carton box tape(18
rolls/carton) |
@ |
can be covered by ACT tape system |
and 8.1 square meter(m2) pipe
surface can be covered.. |
@ |
by 55% ovelap. |
@ |
@ |
@ |
@ |
@ |
@ |
@ |
one case of tape = tape area : 18 m2 per one man-day = wrapping area
8.1m2 per one man-day |
@ |
|
@ |
@ |
@ |
@ |
@ |
@ |
@ |
@ |
That is, covering length of pipe by man/day is as follows. |
@ |
@ |
@ |
@ |
|
Nominal Dia. |
tape width |
Necessary |
Length of |
@ |
@ |
@ |
@ |
|
of pipe |
(m/m) |
man-day |
pipe per day |
@ |
@ |
@ |
@ |
|
4" |
100 |
1 |
23m |
@ |
@ |
@ |
@ |
|
6" |
150 |
1 |
16m |
@ |
@ |
@ |
@ |
|
8" |
200 |
1 |
12m |
@ |
@ |
@ |
@ |
|
10" |
300 |
1 |
10m |
@ |
@ |
@ |
@ |
|
12" |
300 |
2 |
16m |
@ |
@ |
@ |
@ |
|
14" |
300 |
2 |
14m |
@ |
@ |
@ |
@ |
|
16" |
300 |
2 |
13m |
@ |
@ |
@ |
@ |
|
@ |
@ |
@ |
@ |
@ |
@ |
@ |
@ |
2) For straight pipe of dia. 3" or less |
@ |
@ |
@ |
@ |
@ |
@ |
In case of the small size pipe, 1/3 of one carton tape :
6 square meter(m2) of tape can be |
@ |
covered by ACT tape system and 2.7
square meter(m2) pipe surface can be covered |
@ |
@ |
by 55% overlap. |
@ |
@ |
@ |
@ |
@ |
@ |
@ |
1/3 of one case tape=tape area:6 m2 per a man-day=wrapping area of
pipe:2.7m2 per a man-day |
@ |
|
@ |
@ |
@ |
@ |
@ |
@ |
@ |
@ |
That is, covering length of pipe by man/day is as follows. |
@ |
@ |
@ |
@ |
|
Nominal Dia. |
tape width |
Necessary |
Length of |
@ |
@ |
@ |
@ |
|
of pipe |
(m/m) |
man-day |
pipe per day |
@ |
@ |
@ |
@ |
|
1/2" |
50 |
1 |
25m |
@ |
@ |
@ |
@ |
|
1" |
50 |
1 |
25m |
@ |
@ |
@ |
@ |
|
1-1/2" |
50 |
1 |
20m |
@ |
@ |
@ |
@ |
|
2" |
50 |
1 |
14m |
@ |
@ |
@ |
@ |
|
3" |
50 |
1 |
10m |
@ |
@ |
@ |
@ |
|
@ |
@ |
@ |
@ |
@ |
@ |
@ |
@ |
|
@ |
@ |
@ |
@ |
@ |
@ |
@ |
@ |